
Product Hrilhfiahna
Domestic hot water heat exchange unit te hi hmun hrang hranga domestic hot water mamawh phuhrukna tura ruahman bik, integrated heat exchange device an ni.Core atan high-efficiency heat exchanger (a tam zawk chu plate emaw shell-leh-tube type) a hmang a, circulating pump, temperature control valve, filter, leh intelligent control ang chi component te a hmang bawk cabinets.Centralized heating network, boiler, heat pump, leh heat source dang atanga lumna a transfer thin to cold water in domestic water pipes, quickly heating the cold water to a temperature that meets domestic use standards (a tlangpuiin 35-55℃).A hmangtute tan in chhunga tui lum supply nghet, him leh energy hmang tlem thei tak a pe a, hotel, residence, hospital leh hmun danga domestic hot water system hmanraw bulpui ber a ni.
Product Features te pawh a awm
1.Efficiency sang tak a neiheat inthlak danglamnaleh rang taka lumna:Thermal conductivity sang tak nei heat exchange element (stainless steel plate heat exchanger 304 ang chi) a hmang a, chu chuan hot leh cold media inkara contact area lian tak a siam a, heat transfer efficiency sang tak a siam bawk.Tui lum chu hun rei lote chhungin set temperature-ah a ti lum thei a, peak hour-a tui lum supply chak tak mamawhna a phuhruk thei a, thermal efficiency 90% aia tam a nei bawk.
2.Temperature control dik tak, tui lumna nghet tak;High-precision temperature sensor leh intelligent temperature control system hmanga thuam a nih avangin tui lum chhuahna temperature chu real time-in a enfiah a, heat source medium-a flow rate chu automatic-in a siamrem a, chu chuan tui lum temperature inthlak danglamna chu ±1℃chhunga control a nih theih nan a ti a, hei hian tui lum temperature inthlak danglam nghal mai loh nan leh user comfort a ti tha zawk a ni.
3.Hriselna lama humhalhna kimchang:Safety protection device hrang hrang a nei a, chung zingah chuan over-temperature protection (tui lum lutuk a nih chuan heat source chu automatic-in a titawp), over-pressure protection (system pressure a awm loh chuan safety valve chu pressure chhuah tir turin a trigger), leh leakage protection (electric components-in current a leak chuan power chu automatic-in a titawp thin).Impact tihtlem nan anti-scaling design a dah tel bawk of scale buildup on the equipment leh him taka enkawl hmalakna.
4.Energy humhalh leh emission tihtlem nasa tak:Heat source consumption tihtlem nan waste heat recovery (bathing wastewater atanga waste heat lakchhuah ang chi) a thlawp a; model thenkhatah chuan variable frequency circulating pumps dah a ni.Tui lum hman zat a zirin pump speed chu automatic-in a inthlak thei a, hei hian energy hman tul loh a tihtlem phah a ni. Tui lum tihlumna hmanraw hlui nena khaikhin chuan energy save rate hi 15%-30% a tling thei a ni
5.Instal awlsam leh compact:Modular integrated design adopt-in, component zawng zawng chu unified base-ah pre-install a ni a, chu chu hman a nih theih nan inlet leh outlet water pipe leh power supply chauh chu hmunah connect a ngai a ni.No complex assembly required hmanrua chu a tlem a, traditional decentralized hot water system hmun 1/2 atanga 1/3 chauh a luah a, chu chuan hmanrua room tenau emaw, basement space emaw atan a tha hle
6.Enkawlna awlsam leh dam rei tak:Heat exchanger hian detachable structure (plate heat exchanger removable leh washable plate nei ang chi) a hmang a, chu chuan scale leh bawlhhlawh te tihfai fo a ti awlsam a ni.Core components te hi corrosion-resistant materials (304 stainless steel, copper alloy, etc.) atanga siam a ni a, chu chuan corrosion resistance leh aging resistance chak tak a nei a ni. Enkawlna pangngai hnuaiah chuan hmanrua hi kum 8-12 chhung a daih thei a ni
Product Hnathawh te
Core Heating hnathawh dan
Heat hi heat source (high-temperature hot water emaw steam ang chi) atanga heat exchanger hmangin tui lum ah a transfer a, chu chuan tui lum chu a lum nghal vat thei a ni.Kan hmangtute tan in chhunga tui lum, a mamawh temperature phuhruk thei tur kan pe chhunzawm zel a, nitin mamawh, silfai, inbual, leh tihfai te a phuhruk thei a ni
Temperature supply reng reng hnathawh:
Tui lum hman a tlem emaw, a tawp emaw chuan system hian circulation leh heat preservation mode chu a activate nghal a, circulation pump hmangin pipe chhunga tui lum chu a circulate chhunzawm zel a ni.Pipe chhunga tui temperature nghet tak vawn reng hian hman leh hunah tui lum a chhuah loh nan a veng a, chu chuan "instant hot water" a ti thei a ni.
Intelligent taka start/stop leh siamrem dan:
PLC intelligent control system hmanga thuam a nih avangin, hman hun tur ruat lawk angin (residential building-a zing leh tlai tui hman tam ber hun ang chi) angin automatic-in a intan thei a, a tawp thei bawk.Chutih rual chuan, heat source input leh circulation pump speed chu real-time hot water consumption angin dynamically-in a mamawh tak tak nena inmil turin a siamrem thei a, energy hmanral pawh a tihtlem thei bawk.
Tui filtration leh tihthianghlim: 1.1.
Built-in precision filter (filtration accuracy>=40μm) hian tui chhunga bawlhhlawh, silt, rust, leh particulate matter te chu a intercept thei a ni.Heat exchanger channel leh tui lum pipe-a bawlhhlawh awmte a tihkhawtlai loh nan, tui lum thianghlim quality a enkawl a, hmanrua leh pipe-te service life pawh a ti rei thei bawk.
Fault diagnosis leh alarm: 1.1.
Intelligent control cabinet hian hmanrua hman dan parameter (tui temperature, pressure, current, flow rate) te chu real time-in a enfiah thin. Over-temperature, over-pressure, pump failure ang chi harsatna a awm chuan system chuan audible leh visual alarm a pe chhuak nghal a, screen-ah fault awm chhan a tarlang a, maintenance personnel-te harsatna chinfel leh siamthat rang zawka tih awlsam nan fault information chu a record a ni
Remote atanga enkawl leh enkawl dan:
Model thenkhat chuan IoT access an support a, hei hian mobile app emaw computer backend hmangin device operating status, hot water supply, leh energy consumption data te chu real time-in a en thei a ni.Remote atangin tui temperature a set thei bawk a, operating mode pawh a siamrem thei bawk a, unattended intelligent management a nei thei bawk
A hmanna huam chin
In luah tur hmun hrang hrang
High-rise residential community, villa complex, apartment building, etc. tan a tha a, a chhunga chengte chu inbualna, inbualna, leh kitchen tihfai nan in chhunga tui lum a pe a, chhungkaw za tam tak atanga sang tam tak centralized hot water supply mamawh chu a phuhruk thei bawk
Hotel leh restaurant hrang hrangah te
Hei hian star-rated hotel, budget hotel, guesthouse, restaurant, leh eatery te a huam a, heng zawng zawng hian guest room leh restaurant patron te tan darkar 24{3}}hour hot water supply nghet tak a mamawh vek a ni.High-flow, high-frequency hot water usage scenario atan a tha a, peak hour-ah tui lum supply tling tak a awm theih nan a tha a ni zing leh tlai inbualna peaks).
Damdawi lam leh tar enkawlna hmun
Chung zingah chuan general hospital, specialized hospital, nursing home, leh care facility te pawh a tel a, chung zawng zawng chuan faina tehfung (tui lum leh tui thianghlim quality nghet) zawm thei tui lum pek vek tur a ni.Damlo enkawlna, damdawi lam thawktute tana tihfai, leh tarte tana inbualna ang chi hmanna atan chuan hmanrua himna leh nghet tak chuan medical-grade mamawh a tlin a ngai a ni.
Mipui leh sumdawnna hmunpui
Multi-user, decentralized hot water usage scenarios tan a tha a, chu chu school (primary leh secondary school, university dormitory leh canteen), office building (staff restroom leh tea room), gym (shower room), swimming pool (shower leh tui thianghlim), leh shopping mall (public restroom hot water supply) te a ni
Leisure leh service neihna hmun a ni
Hei hian hot spring resort, water park (shower atan), beauty salon, leh foot massage parlor ang chi establishment te a huam a, chung zawng zawngah chuan tui lum chu temperature remchang takah supply chhunzawm zel a ngai a ni. Scenario thenkhatah chuan waste heat recovery system te pawh dah tel a ngai a, hei hian operating cost tihtlem a ni.
Industrial leh hmun bik hrang hrangah te
Factory hnathawkte dormitory leh sakna hmuna temporary living area-a centralized hot water supply atan a tha; ei leh in siamna hmun (food-grade hygiene standards zawm thei tui lum tihfai), kindergarten (safe and anti-scalding hot water supply), leh tui lum mamawh bik nei scenario dangah pawh hman theih a ni.
Heat exchanger unit chungchang hriat belh duh emaw, lei duh emaw i nih chuan 9988xiaoshuai@gmail.com ah email thawn la, message i hmuh hnuah a hun takah kan chhang ang che!
Professional team te an ni
Kan company hian technical personnel te chu a bulpui ber hmangin after-sales service team quality sang tak-a thuam a ni a, a hmangtute hnen atanga service information notification a dawn hunah a hun taka feedback a pe ang.
Darkar 7x24 chhung a rawn thawn thei
Kan company hian kan thil zawrh te hi a thlawnin technical support a pe a, a kaihhnawih mipa te tan technical training a buatsaih bawk.

hot tags .: domestic hot water heat exchanger unit, China ram chhunga tui lum heat exchanger unit siamtu, supplier, factory


