HVAC tan heat exchanger a ni

HVAC tan heat exchanger a ni

HVAC plate heat exchanger hi HVAC system atana siam bik, high-efficiency heat exchange device a ni. Chumi
compact flow channel through siamin cold leh hot media te heat exchange chak tak a ti thei
corrugated metal plate hmanga siam a ni. Energy save, flexibility, leh safety te ang chi thatna a nei a, a zau hle bawk
civil building ang chi field hrang hranga temperature regulation leh energy recovery mamawhna atana hman tur,
industrial production, tui lum supply, leh energy thar siam chhuah te a ni.
Inquiry thawn rawh .
modular-1
Product awmzia sawifiahna

Heat exchanger chu heat exchange device efficiency sang tak, heat, ventilation, leh air conditioning (HVAC) system atana siam bik a ni. Stamped corrugated metal plates stacked leh sealed together atanga siam heat exchange core hmangin hot leh cold fluids inkara heat transfer a ti thei a ni.A core principle chu plate inkara narrow flow channel siam te hmangin cold leh hot media te chu a kalh emaw hmalam emaw a luang chhuak thei tur leh metal plate te thermal conductivity sang tak hmanga rang taka heat inthlakthleng theihna tur a ni.He equipment hian energy a tawk a ni HVAC system-te recovery leh temperature regulation mamawh, heating, cooling, leh hot water supply te pawh a tel a, a pawimawh ber a ni HVAC engineering lama energy hman tangkai theihna tur a ni.

1

Product Features te pawh a awm

 

1.High-efficiency a neiheat inthlak danglamnaleh energy hmanna sang tak: Corrugated plate-te special structure hian flow channel-ah turbulence nasa tak a siam a, hei hian heat transfer coefficient (K value) nasa takin a tichangtlung a ni. Heat transfer efficiency hi traditional shell leh tube heat exchanger aiin a let 3-5 a ni. Temperature danglamna tlemte nen heat exchange chak tak a ti thei a, energy waste a tihtlem thei a, system-a energy-saving effect pawh a ti tha thei bawk.

2.Compact structure leh footprint te tak te:Plate te hian densely stacked design an hmang a, unit volume khata heat exchange area chu shell leh tube heat exchanger aiin a let 5-10 a tling thei a ni. Heat exchange mamawh ang chiah hnuaiah hian hmanrua volume hi traditional heat exchanger aiin 1/3-1/5 chauh a ni a, a rit pawh a rit zawk a, hei hian hmun remchang lo machine room, ceiling emaw equipment mezzanine-ah te dah a awlsam a, civil engineering leh installation senso a ti tlem a ni.

3.Flexible expansion leh adaptability chak tak:Modular assembly method hmangin HVAC system load inthlak danglamna (building-a hmun thar dah belh emaw, peak load siamrem emaw ang chi) angin heat exchange panel tihpun emaw tihtlem emaw, heat exchange unit dah belh emaw hmangin system chu a inthlak danglam thei a ni. Hei hian system pumpui thlak a ngai tawh lo va, project lian leh te, a tir lama sak leh a hnu lama siamthat ngai te nena inmil tura siam a ni.

4.Resistance loss hniam leh operating cost hniam:Optimized flow channel design hian fluid flow resistance a ti tlem a, circulating water pump-a energy hman a tihtlem bawk; chutih rual chuan plate smooth surface chu scaling a awm lo va, chu chuan maintenance cycle rei tak leh tihfai awlsam (removable leh washable structure) a thlen a, chu chuan system kalpui leh enkawlna senso a tihtlem phah a ni.

5.Hrisel, rintlak, leh rei tak-dai thei:Panel te hi corrosion-resistant materials 304/316L stainless steel leh titanium alloy hmanga siam a ni a, gasket te hi food-grade rubber emaw fluororubber emaw hmanga siam a ni thung. Temperature range zau tak (-40℃~180℃) leh stable pressure resistance (2.5MPa thleng) an nei a, hei hian HVAC system-a hnathawh dan khirh tak takah an insiamrem thei a ni. An rawngbawlna hun chhung hi kum 10-15 vel a ni thei

6.Environment tichhe lo leh boruak bawlhhlawh-free:Heat exchange process chhung hian cold leh hot media te hi a inthen vek a, cross-contamination hlauhawmna a awm tawh lo. Hei hian damdawi in-a tui lum supply leh HVAC system ang chi application-a faina mamawh sang tak a tlin a ni. Chutih rual chuan energy recovery theihna sang tak hian fossil fuel hman leh carbon emission a tihtlem a, green building leh environment humhalhna atana thil tulte a zawm a ni.

 

Product Hnathawh te

Heat exchange-a hnathawh bulpui ber

HVAC system-a "energy transfer station" a nih angin, cold leh hot media inkarah heat transfer tha tak a nei thei a ni. Entirnan, heating system-ah chuan boiler-in tui lum-temperature sang tak a siam a\\angin indoor circulating water-ah a lumna chu a transfer a cooling system-ah chuan chiller-in a siam chhuah low-temperature chilled water atanga lumna chu indoor return air-ah a transfer a, chu chuan cooling a ti thei a ni

01

Energy lakchhuah leh hman tangkai dan

Energy efficiency tihchangtlun nan HVAC system atanga bawlhhlawh lumna emaw, lumna emaw lakchhuah. Entirnan, air conditioning exhaust cooling (summer) emaw heating (winter) emaw lak let lehin boruak thianghlim pre-treat leh air conditioning unit-a load tihtlem industrial wastewater leh flue gas atanga bawlhhlawh lumna lakchhuahna chu building lumna emaw, in chhunga tui lum tihlumna atan emaw a ni a, chu chuan energy hman a tihtlem phah a ni.

02

Temperature control dik tak a ni

Plate-te medium flow rate emaw heat exchange area emaw siamrem a nih chuan, output medium temperature chu operating condition hrang hrang hnuaia HVAC system-in temperature mamawh phuhruk turin chiang takin control theih a ni. Entirnan, indoor temperature sensor atanga feedback kan dawn dan atang chuan heat exchange efficiency chu dynamically adjust theih a ni a, chu chuan indoor temperature chu set range chhungah a awm reng theih nan (eg, thlasik laiin 18-22 degree, thlasik laiin 24-26 degree).

03

System venhimna leh hnathawh dan nghet tak

Anti-scaling leh anti-corrosion property tha tak a nei a, system blockage leh equipment wear tihziaawmna a ni a, HVAC system chu hun rei tak-stable operation a nih theih nan a enkawl bawk model thenkhatah chuan temperature leh pressure monitoring interface dah a ni a, chu chu control system nen inzawmkhawmin over-temperature leh over-pressure alarm te realise theih a ni a, hei hian system operational safety a ti tha zawk a ni.

04

Tui lum leh vawt inthen leh inthiarfihlim

Hei hian hot leh cold media inkara physical isolation a thlen a, system chhunga loop hrang hrangte temperature mamawh phuhruk rualin media hrang hrang inkara cross-contamination a veng bawk. Entirnan, in chhunga tui lum leh tui lumna hian heat source an insem hian plate heat exchanger chuan media pahnih chu a isolated a, hei hian heating system pressure leh temperature stability tichhe lovin in chhunga tui lum thianghlimna a tichiang a ni.

05

A hmanna huam chin
 
 
 

Civil building sector-ah chuan a hlawhtling hle

Hei hian civil leh vantlang in hrang hrang, chenna in, office building, shopping mall, hotel, damdawi in, sikul, leh nursing home te a huam a ni. Building chhunga temperature regulation leh tui lum hman dan mamawh phuhruk nan centralized heating/cooling system, air conditioning leh ventilation system, leh centralized emaw individual domestic hot water supply system te nen a inmil a ni

 
 

Industrial production sector ah hian thil siam chhuah a ni

Factory workshop-a air conditioning leh cooling system atan a tha a, thil siamna hmanrua atana cooling system atan a tha a, damdawi, electronics, leh food processing-a industry-a process cooling/heating mamawhna atan a tha bawk. Industrial wastewater leh flue gas atanga waste heat recovery atan pawh hman theih a ni a, secondary energy hman theihna tur leh production energy hman tlem theihna tur a ni.

 
 

Energy thar leh boruak humhalh kawngah te

Energy system thar, ground source heat pump, air source heat pump, leh solar heating te tan pawha hman tlak core heat exchange unit a ni. Data center server room-a precision air conditioning cooling leh green building-a energy recovery ang chi scenario-ah pawh hman theih a ni a, hei hian environment humhalhna, energy humhalhna, leh low-carbon operation-ah a pui a ni.

 
 

Specialized application area hrang hrang zingah hian

cold chain logistics warehouse-a temperature control, rail transit (subway, high-speed rail) station leh carriage-a heat exchange, leh lawng leh tuipui kama platform-a HVAC leh hot water supply system, boruak bik-a temperature control leh energy transfer mamawhna nena inmil.

 
Anyang Tengrui chakna humhalhna hmanrua Co., Ltd.

Heat exchanger unit chungchang hriat belh duh emaw, lei duh tan emaw email thawn theih a ni9988xiaoshuai@gmail.com, message kan hmuh hnuah a hun takah kan chhang ang che!

Professional team te an ni

Khawvel pumah mithiam 29,000+ an awm
Senior project manager te hian project kawng tinreng chu tha takin an thunun a ni

Darkar 7x24 chhung a rawn thawn thei

Kan company hian kan thil zawrh te hi a thlawnin technical support a pe a, a kaihhnawih mipa te tan technical training a buatsaih bawk.

back
 

Tunah hian biak theih reng e

hot tags .: HVAC tan heat exchanger, China HVAC siamtu, supplier, factory tan heat exchanger a ni