Heating Station-a Heat Exchanger Unit awmte

Heating Station-a Heat Exchanger Unit awmte

Centralized heating system-a hmanraw bulpui ber hian heat exchanger, pump set, control system, etc. te chu a thlunzawm a, to
primary network (temperature sang) inkara heat energy transfer leh temperature, pressure leh flow regulation te hriatthiamna
heat source) leh secondary network (user lam) te a ni. Heat source leh the...
user.
Inquiry thawn rawh .
modular-1
Heat exchanger a niunit hrang hrang chu heating station-ah te dah a ni

Heating station-a heat exchange unit te hi centralized heating system-a heat exchange hmanrua bulpui ber a ni. Primary network (high-temperature heat sources (high-temperature heat sources, municipal heating network leh boiler hot water ang chi) atanga secondary network (low-temperature user side, building heating leh domestic hot water system ang chi) ah high-efficiency heat exchanger hmangin heat energy an transfer thin.A rualin temperature, pressure leh flow te fing taka control theih a ni a, chu chuan a siam thei a ni key hub hian heat source leh end user te a thlunzawm a ni.He unit hian core components a integrate a ni heat exchanger, circulating pump, makeup water pump, valve, instrument, leh control system te ang chi te, modular design a hmang a ni.A mamawh tak tak angin a inthlak danglam thei a, centralized heating scenario hrang hrangah hman a ni nasa hle.

 

 

Inelna lama hmasawnna

Company hian a khingpuite nena khaikhin chuan a chakna leh chak lohna te hriatchhuah tumin competitive advantage analysis an nei a ni.

Efficiency sang tak leh energy-saving tha tak leh heat exchange efficiency ropui tak

Core heat exchange element atan plate heat exchanger emaw shell-leh-tube heat exchanger emaw a hmang a ni.High heat transfer coefficient (plate heat exchanger-te heat transfer coefficient chu 3000-5000W/(㎡・℃) a thleng thei), heat exchange efficiency chu 15%-30%-in a tisang a, hei hian a hman dan a tipung thei a ni heat source heat energy leh energy hloh tihtlem;A addition nen of variable frequency energy-saving technology, circulating pump leh water supply pump te hian an operating power chu load angin dynamically-in an siamrem thei a, hei hian energy consumption a ti tlem zual hle

01

Control fing tak, hnathawh dan nghet leh rintlak

PLC intelligent control system hmanga thuam, detection elements temperature sensor, pressure sensor, leh flow meter te inzawmkhawmna a ni.Primary leh secondary network-a temperature, pressure, leh flow parameter te chu real time-in a enfiah thei a, valve hawn leh pump speed chu automatic-in a siamrem thei a, unattended automatic operation a ti thei bawk;He system hian safety protection function tam tak a nei a, chung zingah chuan overload protection, water shortage protection, leh over-temperature leh over-temperature leh over-pressure alarms, hmanraw chhiat lohna tur tha takin a veng thei leh hnathawhna lama dinhmun nghet tak neih theihna tur a ni

02

Installation leh maintenance awlsam zawka hman theih turin modular design:

Unit hian integrated modular design a hmang a, unit kimchang anga thawn chhuah hmain factory-ah prefabricated leh commission a ni.A hman theih nan inlet leh outlet pipe leh power supply chauh chu hmunah connect a ngai a, hei hian installation cycle chu 50% aia tam a ti tawi a;The core components are rationally laid out, with reserved space for maintenance, and the easily damaged parts are highly interchangeable, a hnu lama enkawlna leh thlak danglamna awlsam zawka siam leh hnathawh leh enkawlna senso tihtlem.

03

Wide adaptability leh flexible customization a awm bawk

Heat exchanger chi (plate type, shell leh tube type), pump set specification, leh control mode (manual/semi-automatic/fully automatic) te chu user-te heat source parameter (temperature, pressure), heating area, load mamawh, etc. angin flexible takin configure theih a ni.Heating station size hrang hrang (residential community, commercial complex, industrial plant, etc.), leh a lumna hmun chu unit pakhat hian 500-100,000m vel a huam thei.

04

Environment friendly leh low-noise, green leh friendly

 Low-noise pump set leh optimized airflow design hmang hian, operating noise chu 75dB (A) aia tlem emaw, a tlukpui emaw a ni a, hei hian indoor leh outdoor noise standard a tlin a ni;He hmanrua hi food-grade stainless steel leh carbon steel hmanga siam niin anti-corrosion treatment hmanga siam a ni a, pollutant emission awm lo leh thermal energy utilization rate sang tak a awm a, fossil energy a tihtlem phah a ni consumption leh green heating-a thawhhlawk tak a ni.

05

 

Product Hnathawh te

 

1. Heat exchange hnathawh dan

Core function chu primary network-a tui lum -temperature sang tak leh secondary network-a tui lum lum{1}}temperature hniam inkara heat exchange tha tak neih a ni.Secondary network tui temperature hi a hmangtute mamawh temperature (heating water supply temperature 45-60℃, domestic hot water temperature temperature 50-60℃) thlenga tihsan a ni a, hei hian heating leh domestic hot water atana heating mamawh phuhruk a ni.

2. Parameter control dan tur

Intelligent control system hian primary network regulating valve hawnna chu automatic-in a siamrem a, chu chuan heat exchange rate a control thei a; leh secondary network flow nghet tak neih theih nan circulating pump speed a siamrem bawk.System tui tlakchham emaw overpressure emaw ven nan secondary network system pressure chu set range (a tlangpuiin 0.3-0.6 MPa) chhunga awm reng turin water supply pump hnathawh dan siamrem rawh.

3. Hriselna humhalhna hnathawh

Safety protection hrang hrang a nei a: tui tlakchhamna laka invenna (secondary network tui level set value aia hniam a nih chuan automatic shutdown leh alarm), over-temperature protection (primary emaw secondary network tui temperature-in limit a pelh chuan regulating valve khar la, alarm), over-pressure protection (system pressure-in standard a pelh chuan pressure relief valve automatic-a hawn), leh overload protection (system pressure-in standard a pelh chuan pressure relief valve automatic-a hawn) te a ni pump current a tam lutuk chuan shutdown), hmanrua himna tur leh tihdan.

4. Metering leh monitoring hnathawh dan

Flow meter leh heat meter te a inzawm khawm a, primary leh secondary network-a flow leh heat consumption te real-time monitoring a siam thei a ni. Data hi dahkhawm leh thawnchhuah theih a ni.He system hian heating company te tan energy hman dan statistics leh billing calculation te a siam awlsam a; tin, real-time parameters temperature leh pressure te pawh a lantir bawk a, hei hian maintenance personnel te chuan equipment operating status chu real time in a enfiah thei a ni.

5. Fault alarm leh self{1}}test function te

Equipment chu a pangngai lo taka a thawh chuan (sensor failure, pump set failure, valve jamming, etc.) chuan system chuan audible leh visual alarm a pe chhuak nghal mai ang.Control panel-ah fault code a tarlang a, chu chuan problem identification rang tak a nei a thil dik lo awm thei te proactive taka hriatchhuah nan leh downtime risk tihtlem nan periodic self-checks te pawh a support bawk.

A hmanna huam chin
 
 

'lt Creative nena thawh dun hi a ropui khawp mai. amazingy organized,inbiak pawh awlsam. responsive with next iterations,leh hnathawh mawi tak tak.

 

Civil building sector-ah chuan a hlawhtling hle

residential community, apartment building, villa, office building, hospital, school, hotel, shopping mall, leh civil building dangtea centralized heating leh domestic hot water supply atan a tha hle.Hei hi khawpui centralized heating network-a terminal heating station-a hmanraw bulpui ber a ni a, regional boiler room-te tana supporting heat exchange system atan pawh hman theih a ni bawk.

 
 

Industrial production sector ah hian thil siam chhuah a ni

Industrial plant-a process heat atan hman a ni (chemical, textile, food processing, leh electronics siamna industry-a heating leh temperature control process ang chi), workshop heating, leh hnathawkte tana tui lum supply atan hman a ni.Specialized unit-te chu industrial heating-a parameter bik (high temperature, high pressure, leh large flow rate ang chi)-in production-a personalized heating mamawh phuhruk turin customized theih a ni.

 
 

Mipui hmanraw siamna kawngah

vantlang hmun lian tak tak, stadium, convention center, airport, rel station, leh subway station-a heating leh air conditioning system-a heat exchange atan a tha a, vantlang hmuna boruak lum leh vawt nuam tak a awm theih nan a tha.

 
 

Dilna dangte pawh

Energy heating system thar (ground source heat pump leh air source heat pump heating system-a secondary heat exchange ang chi), heating system hlui siamthat leh tihchangtlunna atan (heat exchange hmanrua tha lo thlak leh heating efficiency tihchangtlun nan), thingtlang hmuna centralized heating leh distributed heating ang chi scenario-ah te hman theih a ni.

 
Anyang Tengrui chakna humhalhna hmanrua Co., Ltd.

Heat exchanger unit chungchang hriat belh duh emaw, lei duh emaw i nih chuan 9988xiaoshuai@gmail.com ah email thawn la, message i hmuh hnuah a hun takah kan chhang ang che!

Professional team te an ni

Kan company hian technical personnel te chu a bulpui ber hmangin after-sales service team quality sang tak-a thuam a ni a, a hmangtute hnen atanga service information notification a dawn hunah a hun taka feedback a pe ang.

Darkar 7x24 chhung a rawn thawn thei

Kan company hian kan thil zawrh te hi a thlawnin technical support a pe a, a kaihhnawih mipa te tan technical training a buatsaih bawk.

back

 

hot tags .: heat station-a heat exchanger unit awmte, China-a heat exchanger unit siamtute, supplier-te, factory-a awmte