Product Definition: Industrial process-a temperature control na atana hmanraw pawimawh ber berte
Process Water Heat Exchange Unit te hi industrial production process atana siam bik heat exchange system inzawmkhawm a ni a, chu chu process medium temperature, flow rate, leh pressure dik taka control tumna bulpui ber a ni (mainly process water).Heat exchanger, pump set, valve, leh control system te ang chi components te chu a inmil tur a ni a, chu chuan cold leh heat te chu a ti thei a ni. Heat exchange medium chi khat chauh a ni lo.Heat exchange mode hrang hrang tui-Tui, tui{4}} leh tuiah te, hnathawh dan azirin heat transfer oil te nen a inmil thei a, industrial production-a hmanraw pawimawh tak a ni a, chu chuan stability a neih theih nan leh energy utilization a tichak thei a ni.
Product Features: Process mamawh ang zela hman theih, efficiency sang leh rintlakna inthlauhna
Product Functions: Dimension zawng zawnga a kalphung nghet taka awm theihna tur enfiah .
Temperature control dik tak .
:Heat transfer hmangin .Heat Exchangers te pawh a awm bawk.leh closed-Loop regulation of the control system.Process water temperature chu set range chhungah a stabilise a, chu chuan process hrang hrang, reaction, distillation, drying, leh cooling te temperature mamawhna khauh tak a tlin theih nan a ni.
01
Flow leh pressure matching:
Process load a inthlak dan azirin variable frequency pump set chuan output flow rate chu automatic in a siam rem a, pressure regulating valve nen thawk hovin system pressure nghet tak a awm reng a, flow fluctuation avanga process parameter pangngai lo te chu a veng thei a ni.
02
media tihthianghlimna leh venhimna;
Model ṭhenkhat chuan filtration system an thlunzawm a, chu chuan bawlhhlawh leh suspended solids chu process water aṭanga paih chhuah a ni a, hei hian heat exchanger clogging a veng a Tin, corrosion inhibition leh descaling system te nen pawh paired theih a ni a, chu chuan hmanrua leh process piping service life a ti rei thei bawk.
03
Bawlhhlawh lumna lak let leh hman tangkai dan:
Waste heat resources, high-temperature process bawlhhlawh leh exhaust gas te tan chuan heat exchange unit hmangin heat recover to recover heat to heat low-temperature process water aiah, traditional heat source thenkhat, steam leh electric heating te chu a thlak a, chu chuan production energy consumption leh operating cost a tihtlem phah a ni.
04
Emergency support hnathawh dan tur .
Backup pump set leh manual adjustment mode hmanga thuam a nih avangin automatic system a chhiat chuan Emergency Operation Mode-ah a inthlak nghal vat thei a, process tihtawp avanga hloh tur a veng thei bawk.
05
Dilna Site 1.1.
Industrial atanga siam chhuah .
Chemical, petroleum, power (thermal/nuclear), metallurgical, damdawi, leh ei tur siamna workshop, heating/cooling process media atana hman thin.
Building lama puitu tur facility te .
shopping mall lian tak tak, office building, leh chenna in hrang hrangte tan central heating/cooling system; Damdawi in leh sikul hrang hrang tan tui lum supply station a awm bawk.
Scenarios bik a awm em .
Data center cooling system, tui bawlhhlawh sawngbawlna plant temperature control process, leh energy thar siamna atana thermal management components (photovoltaic/wind power)
Core components leh functional analysis .
Process Water Heat Exchanger hi thermal device inzawmkhawm a ni. An core components te hian heat transfer leh system stability an neih theih nan an thawk ho thin. Key components te chu:.
Heat Exchangers te pawh a awm bawk.
core heat transfer elements te a awm bawk. A chi hrang hrangte chu plate heat exchanger (high efficiency, compact, disassemble leh clean awlsam, small to medium flow conditions atana hman tlâk) leh shell{{1} leh{2}}tube heat exchanger (high pressure leh high temperature-a tuar thei, highly adaptable, a tam zawk chu flow rates sang emaw, particle awmna particle-a hman theih tam ber emaw) a ni.Spiral plate heat exchange-te inkara heat exchange-a telna, high heat transfer resistance, suitable for viscous process Water and examplement for the completes water and Media (tui lum leh tui lum ang chi) chu media lum leh lum inkara indirect contact hmangin a kal thei.
Circulation pump:
Process water flow atan power pek a nih avangin pump hi variable frequency pump leh fixed frequency pump ah then a ni. Variable frequency pump te hian an speed chu load inthlak dan azirin automatic in an siam rem thei a, energy hman an tihtlem bakah load inthlak danglamna lian tak nei scenario (chemical reactor-a temperature control ang chi te tan pawh a tha hle).Fixed-Frequency pump te hian structure awlsam tak leh cost hniam tak an nei a, chu chuan stable load conditions atan a tha hle.
Temperature control na hmanrua;
Temperature sensor, valve regulating, leh PLC control system te a awm bawk. Sensor hian process water inlet leh outlet temperature te chu real time-in a enfiah a, PLC-ah signal a thawn chhuak thin.Heat transfer medium/cooling medium (steam valve opening℃leh cold water valve ang chi) flow rate siamrem hian process water temperature chu set range chhungah a awm reng theih nan a enkawl a ni (a dikna chu ±1℃a ni tlangpui).
Filter a ni a .
Process water-a impurities (rust leh particulate matter ang chi) te intercept tur chuan heat exchanger clogging ven tur a ni a, equipment life pawhsei tur a ni a, filter screen precision hi a tlangpuiin 50-100 mesh a ni
Expansion tank 1000 a ni.
:Heating laiin process water volume expansion chu absorb theih nan, balance system pressure a balance theih nan leh pipeline overpressure a awm loh nan. Safety valve, pressure gauges, leh thermometer te hi system safety venna leh operational status monitoring atan hman a ni.
Operation, enkawl, leh harsatna chinfel dan .
A tihfai dan pangngai .
Plate heat exchanger te chu thla 3- thla 3-engtikah tihfai leh tihfai vek tur a ni a, chutih laiin shell- leh -tube heat exchanger te chu chemical (citric acid solution ang chi) hmanga tihfai emaw, high-pressure water hmanga flush emaw theih a ni a, scale leh impurities te chu paih chhuah theih a ni bawk.
Parameter enkawlna: 1.1.
Inlet leh outlet temperature, pressure leh flow rate te chu real time-in enfiah thin ang che. Temperature danglamna a tlahniam emaw, pressure hloh a san chuan heat exchanger chu block a nih thu leh rang taka hmalak a ngai tih a tilang thei.
Lubrication leh enkawl dan:
Thla 6-12 danah circulating pump bearings te chu lubricate la, seals ah leak awm leh awm loh enfiah rawh

Common faults leh solutions: 1.1.
Heat exchange efficiency a tlahniam .
A chhante chu scaling, heat exchanger-a air blockage emaw, valve hawn tlem loh emaw a ni thei.Solution: Heat exchanger tifai la, exhaust valve atanga boruak vent la, valve hawnna chu a rang thei ang bera siam la
System pressure nghet lo tak .
A chhan chu expansion tank-ah pressure tling lo emaw, pipeline leak emaw a ni thei a; Solutions:Expansion tank-a nitrogen pressure tih tlem la, leak awm apiang chu zawng la, siamthat rawh;
Pump unit hi a vibrate a, thawm a nei nasa hle .
A chhan chu impeller imbalance emaw loose foundation emaw a ni thei;solution: impeller siam that leh foundation bolt te kha tikhauh rawh.
Heat exchanger unit chungchang hriat belh duh emaw, lei duh emaw i nih chuan 9988xiaoshuai@gmail.com ah email thawn la, message i hmuh hnuah a hun takah kan reply ang che!
Professional team te .
29,000+ Khawvel pumah mithiamte .
Senior Project Manager te chuan project a thil awm zawng zawng chu tha takin an thunun thei a ni.
7x24 hours a thlen theih
Kan company hian kan thil zawrh te chu a thlawnin technical support a pe a, technical training atan 2019 atan 2019 atan a buatsaih bawk.inphupersonnel te an ni.

hot tags .: Process Water Heat Exchanger Unit, China Process Water Heat Exchanger Unit siamtu, Supplier, Factory