Heat Exchanger hnathawh dan chipchiar taka sawifiahna (Diagram nen) .

Jun 26, 2026 Message pakhat dah la .

1. Heat exchanger hnathawh dan bulpui ber chu eng nge ni?Products Description

 

Heat exchanger principle bulpui ber chu temperature sang-temperature fluid atanga low-temperature fluid-a heat transfer hi a ni a, a tlangpuiin heat conduction leh convection hmangin an pahnih inkara direct contact awm lovin-.
 Temperature sang-temperature fluid hian heat a chhuah a, chu chu heat exchange wall kaltlangin a transfer thin.
 Heat hi metal wall (or heat exchange medium) kaltlangin a kal a ni.
 Low-temperature fluid hian lumna chu a hip lut a, chu chuan temperature a tisang emaw a tlahniam emaw a ni.
 A kalphung zawng zawng hian thermodynamics dan pahnihna a zawm a, chutah chuan lumna chu a takin temperature sang zawk atanga temperature hniam zawkah a luang chhuak thin.

2

II. Engtin nge heat exchanger te hian heat hi an transfer thin?

 

Heat exchanger te hian a bul berah chuan heat transfer tha tak chu mechanism pahnih hmangin an ti thei a, chungte chu conduction leh convection te an ni.

 

• Conduction: Metal wall kaltlangin lumna chu high-temperature lam atanga low-temperature lam ah a transfer thin.

01

 


• Convection: Wall sir lehlama tui luang chhuak hian lumna a phur chhunzawm zel emaw, a pe chhuak emaw a ni.
 

02

 

• Combined effect: Conduction leh convection inzawmkhawm hian heat transfer efficiency zawng zawng a ti sang a ni.

03

 

Radiative heat transfer hi hmanraw thenkhatah pawh a awm thei a, mahse industrial heat exchanger-ah chuan chanvo tlemte chauh a nei a ni.

04

3. Heat exchanger-a flow ruahmanna tlangpui chu engte nge ni?

info-1600-891

Fluid flow kalna lam a zirin heat exchanger-te tan hian primary flow pattern pathum a awm a:
 Co-current flow (parallel flow): Fluid pahnih hi kawng khatah an luang a, temperature danglamna chu a tlahniam zauh zauh thin.
 Counter-current flow (counter-flow): Fluid pahnih hi kawng hrang hrangah an luang a, heat transfer efficiency sang ber an pe a ni.
 Cross-flow: Fluid pahnih hi an inzawm tlat a; he configuration hi a compact a, hman lar tak a ni.
 Chung zingah chuan counter-current arrangement hi industrial application-ah efficiency sang tak mamawhna hmunah hman a ni ber.

4. Heat exchanger chhunga thil awm dan hian engtin nge heat transfer process a nghawng?

 

Structural design hian heat transfer area, flow velocity distribution, leh efficiency te chu direct-in a tichiang a ni.
01.

 

 Heat transfer area lian zawk chuan hun unit khatah heat transfer capacity a ti sang zawk.

 

02.

 

 Flow channel design hian fluid turbulence℃a nghawng a; turbulence sang zawk chuan heat transfer tha zawk a thlen thin.

03.

 

 Wall material-a thermal conductivity sang zawk chuan thermal resistance a ti hniam zawk.

04.

 

 Configuration pangngaiah hian shell-leh-tube, plate, leh spiral chi hrang hrang a awm a, heat transfer characteristic hrang hrang nei vek a ni.

 

 

 

5. Heat exchanger hnathawh laiin eng key formula nge hman?

 

Heat transfer kalphung hi a tlangpuiin heat transfer-a fundamental equation hmangin sawifiah theih a ni.

Heat transfer equation bulpui ber chu:
Q=U × A × ΔTlm tih a ni

Khawnge:

Q: Heat transfer rate (W) a ni.
U: Heat transfer coefficient zawng zawng (W/m2·K) 1.1.
A: Heat transfer area (m2) a ni.
ΔTlm: Logarithmic hmanga boruak lum leh vawt inthlauhna
Equation chhinchhiahna te:
U emaw A emaw tihpun hian heat transfer capacity nasa takin a tipung thei a ni.
Temperature danglamna lian zawk chuan heat transfer atana driving force chak zawk a siam a ni.

2
6. Heat exchanger hnathawh thatna tichhe thei thil pawimawh ber berte chu engte nge ni?
 

Heat transfer efficiency hi engineering factor hrang hrangin a nghawng dun a ni.

 

Fluid property: Heat capacity bik, thermal conductivity, viscosity, etc. a awm thei.
 

01

 

Flow velocity: Flow velocity sang zawk hian a tlangpuiin heat transfer a tichak a, mahse flow resistance a tipung bawk.

02

 

Fouling factor: Fouling hian thermal resistance a tipung a, efficiency a ti tlem bawk.

03

 

Heat transfer area: Area tlem chuan heat transfer theihna sang ber a tikhawtlai.

04

 

 

302cb7020cdb4a571a0333b49117e6ea

Anyang Tengrui chakna humhalhna hmanrua Co., Ltd.

Heat exchanger unit chungchang hriat belh duh emaw, lei duh emaw i nih chuan 9988xiaoshuai@gmail.com ah email thawn la, message i hmuh hnuah a hun takah kan chhang ang che!

Professional team te an ni

Kan company hian technical personnel te chu a bulpui ber hmangin after-sales service team quality sang tak-a thuam a ni a, a hmangtute hnen atanga service information notification a dawn hunah a hun taka feedback a pe ang.

Darkar 7x24 chhung a rawn thawn thei

Kan company hian kan thil zawrh te chu a thlawnin technical support a pe a, a kaihhnawih mipa te tan technical training a buatsaih bawk.

back