Fully Automatic Heat Exchanger Unit-a hnathawh ber berte .

Sep 30, 2025 Message pakhat dah la .

 
Water-water Heat Exchanger Unit

 

Fully Automatic Heat Exchanger Unit-a hnathawh ber berte .

He highly efficient, intelligent heat exchanger unit hi media hrang hrang nei heat exchanger atan hman theih a ni a, chung zingah chuan steam{{0} tui, tui-tui, leh oil-tui te pawh a tel. Plate heat exchanger, circulating pump, tui-feeding pump, decontamination device, piping, valve, instrumentation, leh frequency control system danglam tak a awm a ni. Dilna a awm chuan fully automatic programming system pawh a dah theih bawk. He unit hian heat transfer efficiency sang tak, resistance hniam, structure compact, rintlak, leh simple, intuitive operation a nei a, hei hian efficient leh energy tha tak a siam thei-saving product duh ber a ni.

 
 
 

ChumiAutomatic heat exchanger unit kimchang tak a awm bawk.chu primary network-a heat energy chu secondary network-a heat energy-ah a chantir a, chu chuan user-te heating mamawh a phuhruk thei a ni. A hnuaia function lian ber berte hi a nei a ni:

 

Heat Exchange hnathawh dan: 1.1.Heat Exchanger 1000 a ni..

 

Temperature Regulation: User mamawh leh a hman dan tak tak a zirin secondary network-a tui supply temperature chu automatic-in a siamrem thin. Temperature sensor chuan secondary network-a tui lumna chu real time-in a enfiah a, signal chu control system-ah a pe kir leh a ni. Control system hian primary network-a flow rate emaw, heat exchanger-a operating parameters emaw chu set temperature value hmangin automatic-in a siamrem a, secondary network water temperature chu set range chhungah a dah a, season leh scenario hrang hranga user hrang hrangte heating temperature mamawh a phuhruk bawk.

Pressure control function: Primary leh secondary network-a pressure awm dan a enfiah a, a control bawk. Khawthlang lamah chuan primary network-ah stable pressure a siam a, chu chuan normal supply leh transfer of heat a awm theih nan a pui a ni. A lehlamah chuan, pipe rupture emaw, pressure nasa lutuk avanga hmanrua chhiatna emaw a awm loh nan secondary network-a pressure chu safe range chhunga a control a, chutih rualin pressure hniam chuan heating efficiency a nghawng loh nan a veng bawk. Pressure sensor leh a inmil pressure regulating device hmangin, pressure reducing valve leh water supply pump te hmangin network pressure chu automatic regulation leh stable control a ni.

Heating Heat Exchanger Unit
 
 

Flow Regulation: Heat load inthlak danglam dan a zirin primary leh secondary network-a flow rates chu automatic-in a siamrem thin. User heat demand a san chuan system chuan primary network-a hot water flow rate chu heat exchange tihchangtlun nan a tisang nghal a, chutih rualin secondary network flow rate chu a hun taka leh heat distribution pawh user terminal zawng zawngah a awm theih nan a siamrem bawk. A lehlamah chuan heat demand a tlahniam chuan flow rate pawh chutiang chuan a tlahniam a ni. Flow regulation hi electric control valve ang chi device hmanga tih theih a ni a, precision sang tak leh fast response a pe thei a ni.

 

Automatic Control: Heat exchanger unit chu a enkawl a, a control theih nan automated control system hman a ni. Operator-te chuan control cabinet-ah parameter hrang hrang, temperature, pressure, leh flow te an set mai a ni. System hian device tinte operating status chu a taka hman dan tur dik tak hmangin automatic-in a siamrem a, kut hmanga inrawlh fo a ngai tawh lo. Chubakah, automatic control system hian fault diagnosis leh alarm function a nei a, hei hian real-equipment operating conditions te hun a enkawl thei bawk. Fault a hriat veleh alarm tihchhuah nghal a ni a, hmanrua leh system him taka hman a nih theih nan automatic shutdown leh power cutoff ang chi venhimna tur ruahmanna fel tak siam a ni.

 
 

Heat exchanger unit chungchang hriat belh duh emaw, lei duh emaw i nih chuan 9988xiaoshuai@gmail.com ah email thawn la, message i hmuh hnuah a hun takah kan reply ang che!